Test Code COL7 Anti-Collagen type VII, IgG Antibodies, Serum
Specimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 2 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Method Name
Enzyme-Linked Immunosorbent Assay (ELISA)
Specimen Type
SerumSpecimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time |
---|---|---|
Serum | Refrigerated (preferred) | 14 days |
Frozen | 30 days | |
Ambient | 14 days |
Reject Due To
Gross hemolysis | OK |
Gross lipemia | OK |
Gross icterus | OK |
Clinical Information
Epidermolysis bullosa acquisita and certain other rare immunobullous diseases, including bullous lupus erythematosus, are caused by the development of IgG antibodies directed against collagen type VII, which lead to blisters and erosions that may heal with scarring. Circulating IgG autoantibodies against collagen type VII can be found in patient serum in these conditions.
Reference Values
Collagen type VII
<20 RU/mL (negative)
≥20 RU/mL (positive)
Day(s) Performed
Varies
Report Available
1 to 5 daysPerforming Laboratory

CPT Code Information
83516